Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 457
Filter
1.
Rev. CEFAC ; 26(1): e6923, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1535108

ABSTRACT

ABSTRACT Purpose: to verify if there is an electromyographic difference during maximal (maximum) voluntary contraction of the masseter and temporalis muscles in patients with temporomandibular disorders, before and after speech therapy intervention with and without the use of therapeutic elastic bandages. Methods: an analysis of secondary data from a clinical intervention study, carried out with 17 adult volunteers, diagnosed with temporomandibular muscle dysfunction with or without disc displacement with reduction. The Bandage Group received manual therapy associated with elastic bandages and the No Bandage Group received only manual therapy. Surface electromyography was performed to record the Maximum Voluntary Contraction before and after four weeks of speech therapy intervention. For exploratory analysis, the Mann Whitney and Wilcoxon paired tests were used, with P<0.05. Results: in the Bandage Group, there was a statistically significant decrease in electrical activity during Maximum Voluntary Contraction in the masseter and temporalis muscles on the left side at the post-therapeutic moment. Comparing the pre- and post-intervention between Bandage Group and No Bandage Group, a statistical difference was found in the electrical activity values of the Maximum Voluntary Contraction in the left temporal muscle. Conclusion: manual myofunctional speech therapy, associated or not with the use of therapeutic elastic bandages, impacts the muscle activity of the masseter and temporal muscles during Maximum Voluntary Contraction, whether the values demonstrate relaxation and/or equivalence of the electromyographic values of the masticatory muscles.


RESUMO Objetivo: verificar se há diferença eletromiográfica durante contração voluntária máxima dos músculos masseter e temporal de pacientes com disfunção temporomandibular, antes e após intervenção fonoaudiológica com e sem uso de bandagem elástica terapêutica. Métodos: foi realizada a análise de dados secundários de estudo do tipo intervenção clínica, com 17 voluntárias, adultas, com diagnóstico de disfunção temporomandibular muscular com ou sem deslocamento de disco com redução. O Grupo Bandagem recebeu terapia manual associada à bandagem elástica e o Grupo Sem Bandagem recebeu apenas terapia manual. Foi realizada eletromiografia de superfície para registro da contração voluntária máxima antes e após quatro semanas de intervenção fonoaudiológica. Para análise exploratória foram utilizados os testes: Mann Whitney e Wilcoxon Pareado, com p<0,05. Resultados: no Grupo Bandagem, houve diminuição estatisticamente significante da atividade elétrica durante a Contração Voluntária Máxima nos músculos masseter e temporal do lado esquerdo no momento pós-terapêutico. Na comparação do pré e pós-intervenção entre Grupo Bandagem e Grupo Sem Bandagem, constatou-se diferença estatística nos valores da atividade elétrica de Contração Voluntária Máxima no músculo temporal esquerdo. Conclusão: a terapia fonoaudiológica miofuncional manual, associada ou não ao uso da bandagem elástica terapêutica, impacta a atividade muscular dos músculos masseter e temporal durante a Contração Voluntária Máxima, sejam os valores demonstrando relaxamento e/ou equivalência dos valores eletromiográficos da musculatura mastigatória.

2.
Fisioter. Mov. (Online) ; 37: e37103, 2024. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1528626

ABSTRACT

Abstract Introduction In the context of resistance training, which encompasses both strengthening and rehabilitation, the incorporation of global range exercises demands intense activation of the trunk muscle groups, which play a primary role in body stabilization. The squat, notorious for its complexity and effectiveness in activating stabilizers during execution, raises a central question: whether this exercise recruits the muscles more significantly compared to localized exercises, such as push-ups and trunk exten-sions. Objective To identify the degree of activation of the trunk muscles during squats and compare it with localized exercises for the trunk muscles: lumbar and abdominal. Methods Using surface electromyography, the activation of the iliocostalis, multifidus, internal oblique, external oblique and rectus abdominis muscles was evaluated. The sample included 16 physically active volunteers of both sexes. A repeated measures t-test (α < 0.05) was used as an analysis method. Results The iliocostalis, multifidus and internal oblique muscles showed similar levels of activation both in the squat and in their respective isolated exercises, while the rectus abdominis and external oblique muscles showed greater activity during trunk flexion. Conclusion It is possible to infer that squats are an effective exercise for training the iliocostalis, multifidus and internal oblique muscles, while localized exercises are more suitable for strengthening the external oblique and rectus abdominis muscles. Such conclusion can contribute to optimizing the planning of exercise sessions by replacing isolated trunk exercises with squats.


Resumo Introdução No contexto do treinamento resistido, que engloba tanto o fortalecimento quanto a reabilitação, a incorporação de exercícios de alcance global demanda uma intensa ativação dos grupos musculares do tronco, os quais desempenham um papel primordial na estabilização corporal. O agachamento, notório por sua complexidade e eficácia na ativação dos estabilizadores durante a execução, suscita uma questão central: se o agachamento recruta de forma mais acentuada a musculatura do tronco comparativamente a exercícios localizados, tais como flexões e extensões do tronco. Objetivo Identificar o grau de ativação dos músculos do tronco durante o agachamento e confrontá-lo com exercícios localizados para a musculatura do tronco: lombar e abdominal. Métodos Através da aplicação da eletromiografia de superfície, avaliou-se a ativação dos músculos iliocostal, multífido, oblíquo interno, oblíquo externo e reto abdominal. A amostra englobou 16 voluntários de ambos os gêneros, fisicamente ativos. Empregou-se um teste t de medidas repetidas (α < 0,05) como método de análise. Resultados Os músculos iliocostal, multífido e oblíquo interno manifestaram níveis semelhantes de ativação tanto no agachamento quanto em seus respectivos exercícios isolados, enquanto os músculos reto abdominal e oblíquo externo apresentaram maior atividade durante a flexão do tronco. Conclusão É possível inferir que o agachamento se configura como um exercício eficaz para o treinamento do iliocostal, multífido e oblíquo interno, enquanto os exercícios localizados se revelam mais indicados para o fortalecimento do oblíquo externo e dos músculos reto abdominais. Tais conclusões podem contribuir para a otimização do planejamento de sessões de exercícios, mediante a substituição de exercícios isolados de tronco pelo agachamento.

3.
Arq. neuropsiquiatr ; 81(12): 1040-1052, Dec. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527909

ABSTRACT

Abstract The nerve terminal and muscle membrane compose the neuromuscular junction. After opening the voltage-gated calcium channels, action potentials from the motor axons provoke a cascade for the acetylcholine release from synaptic vesicles to the synaptic cleft, where it binds to its receptor at the muscle membrane for depolarization. Low amplitude compound muscle action potential typically presents in presynaptic disorders, increasing by more than 100% after a 10-second effort in the Lambert-Eaton myasthenic syndrome and less in botulism. Needle electromyography may show myopathic motor unit action potentials and morphological instability ("jiggle") due to impulse blocking. Low-frequency repetitive nerve stimulation (RNS) is helpful in postsynaptic disorders, such as myasthenia gravis and most congenital myasthenic syndromes, where the number of functioning acetylcholine receptors is reduced. Low-frequency RNS with a decrement >10% is abnormal when comparing the 4th to the first compound muscle action potential amplitude. High-frequency RNS is helpful in presynaptic disorders like Lambert-Eaton myasthenic syndrome, botulism, and some rare congenital myasthenic syndromes. The high-frequency RNS releases more calcium, increasing the acetylcholine with a compound muscle action potential increment. Concentric needle records apparent single-fiber action potentials (spikes). A voluntary activation measures the jitter between spikes from two endplates. An electrical activation measures the jitter of one spike (one endplate). The jitter is the most sensitive test for detecting a neuromuscular junction dysfunction. Most neuromuscular junction disorders are responsive to treatment.


Resumo O nervo terminal e a membrana muscular compõem a junção neuromuscular. Após a abertura dos canais de cálcio dependentes de voltagem, os potenciais de ação do axônio motor provocam uma cascata de eventos que libera acetilcolina das vesículas para a fenda sináptica, ligando-se ao receptor na membrana muscular para despolarização. O potencial de ação muscular composto de baixa amplitude ocorre nas desordens pré-sinápticas, aumentando em mais de 100% após esforço de 10 segundos na síndrome miastênica de Lambert-Eaton e menos no botulismo. A eletromiografia pode mostrar potenciais de ação da unidade motora miopáticos e instabilidade morfológica ("jiggle") devido ao bloqueio do impulso. Estimulação nervosa repetitiva (ENR) de baixa frequência é útil nos distúrbios pós-sinápticos, como miastenia gravis e a maioria das síndromes miastênicas congênitas, quando há número reduzido de receptores de acetilcolina funcionantes. ENR de baixa frequência com decremento >10% é anormal comparando-se à amplitude do quarto com o primeiro potencial de ação muscular composto. ENR de alta frequência é útil nas doenças pré-sinápticas, como síndrome miastênica de Lambert-Eaton, botulismo e algumas síndromes miastênicas congênitas raras. ENR de alta frequência libera mais cálcio, aumenta acetilcolina, resultando em incremento do potencial de ação muscular composto. O eletrodo de agulha concêntrico registra potenciais de ação aparente de fibra única (PAAFU). Ativação voluntária mede jitter entre dois PAAFUs (duas junções neuromusculares). Ativação elétrica mede jitter de um PAAFU (uma junção neuromuscular). Jitter é o teste mais sensível para detectar disfunção de junção neuromuscular. A maioria dos distúrbios juncionais é responsiva ao tratamento.

4.
Arq. neuropsiquiatr ; 81(11): 949-955, Nov. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527891

ABSTRACT

Abstract Background Detailed information about the electromyography practice in Brazil is largely unavailable. Objective To evaluate where and how electromyography is performed in Brazil, as well as regional disparities and the professional and academic credentials of electromyographers. Methods We conducted an internet-based survey of active Brazilian electromyographers. The websites of health insurance companies, professional academies, medical cooperatives, online search engines, and social networks in each Brazilian state were screened and we evaluated the credentials of each electromyographer listed in the Brazilian Federal Medical Board (BFMB) registration website and their online curricula vitae in the Brazilian National Council for Scientific and Technological Development (Conselho Nacional de Desenvolvimento Científico e Tecnológico, CNPq, in Portuguese). We also evaluated the same parameters in a control group of non-electromyographer neurologists randomly matched by geographical distribution and gender. Results We found 469 electromyographers (384 neurologists and 85 non-neurologists), with a male predominance. In total, 81.9% were BFMB-certified neurologists, 49.9%, BFMB-certified clinical neurophysiologists, and 10.4%, BFMB-certified physiatrists. Among the non-neurologists, 48.2% were physiatrists. Most electromyographers practiced in states on the Southern and Southeastern regions of Brazil. When adjusted by population, the Federal District and the states of Mato Grosso do Sul and Goiás presented the highest of eletromyographers density. Electromyographers were not more likely to have current/past academic affiliations. Conclusion In Brazil, electromyography is performed predominantly by neurologists, and half of them are BFMB-certified clinical neurophysiologists. The present study highlights regional disparities and may guide government-based initiatives, for instance, to improve the diagnosis of leprosy and the management of neuromuscular disorders within the Brazilian territory.


Resumo Antecedentes Informações detalhadas sobre a prática de eletromiografia no Brasil são em grande parte indisponíveis. Objetivo Avaliar onde e como a eletromiografia é realizada no Brasil, as disparidades regionais, e as credenciais profissionais e acadêmicas dos eletromiografistas. Métodos Realizamos uma enquete via internet de eletromiografistas brasileiros ativos. Foram rastreados sites de operadoras de planos de saúde, academias profissionais médicas, cooperativas médicas, ferramentas de busca online e redes sociais em cada estado brasileiro. Em seguida, avaliamos as credenciais de cada eletromiografista listado no site de registro do Conselho Federal de Medicina (CFM) e seus curricula vitae online no Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq). Também avaliamos os mesmos parâmetros em um grupo controle de neurologistas não eletromiografistas pareados aleatoriamente por distribuição geográfica e gênero. Resultados Encontramos 469 eletromiografistas (384 neurologistas e 85 não neurologistas), com predominância do sexo masculino. Ao todo, 81,9% eram neurologistas com certificação confirmada pelo site do CFM, 49,9%, neurofisiologistas clínicos com certificação confirmada pelo site do CFM, e 10,4%, fisiatras com certificação confirmada pelo mesmo site. Entre os não neurologistas, 48,2% eram fisiatras. A maioria dos eletromiografistas atuava nos estados do Sul e do Sudeste. Quando ajustados pela população, o Distrito Federal e os estados de Mato Grosso do Sul e Goiás apresentaram a maior densidade de eletromiografistas. Os eletromiografistas não eram mais propensos a ter vínculos acadêmicos atuais/passados. Conclusão No Brasil, a eletromiografia é realizada predominantemente por neurologistas, e metade deles são neurofisiologistas clínicos com certificação confirmada pelo site do CFM. Este estudo destacou as disparidades regionais, e pode orientar ações governamentais para, por exemplo, melhorar o diagnóstico da hanseníase e o manejo das doenças neuromusculares no território brasileiro.

5.
Distúrb. comun ; 35(3): e57872, 25/10/2023.
Article in English, Portuguese | LILACS | ID: biblio-1517690

ABSTRACT

Objetivo: A pesquisa tem por objetivo verificar os limiares de repouso eletromiográfico dos músculos masseter e temporal em pacientes com disfunção temporomandibular (DTM) antes e após intervenção fonoaudiológica com e sem a utilização de bandagem elástica terapêutica. Métodos: A coleta contou com 14 participantes do sexo feminino, com idade entre 18 e 40 anos, com diagnóstico de DTM muscular ou mista. As pacientes foram divididas entre dois grupos classificados em: pacientes com bandagem associada à terapia tradicional (CB) e grupo de terapia tradicional (SB). As pacientes inicialmente foram avaliadas pelo exame de eletromiografia de superfície nas situações de contração voluntária máxima e repouso, e após quatro semanas de intervenção, foi realizada nova avaliação com os mesmos instrumentos. A análise dos dados ocorreu de forma quantitativa e qualitativa. Resultados:No grupo SB o músculo masseter direito apresentou aumento dos valores de repouso com significância, foi observado que o mesmo ocorreu para todos os músculos deste grupo, influenciando no equilíbrio da musculatura ipsilateral e contralateral, no entanto sem evidência estatística. O grupo CB não demonstrou valores estatísticos significativos, porém qualitativamente os valores de repouso muscular diminuíram e equilibraram-se de forma contralateral. Conclusão: Não foram observadas mudanças estatisticamente significantes nos limiares eletromiográficos durante repouso dos músculos masseter e temporal em ambos os grupos. Qualitativamente houve aumento dos valores eletromiográficos após terapia manual tradicional em todos os músculos do grupo SB. Com relação ao grupo CB, houve diminuição dos valores do repouso eletromiográfico após terapia, embora sem evidências estatísticas. (AU)


Purpose: Objective: The research aims to verify the electromyographic rest thresholds of the masseter and temporal muscles in patients with temporomandibular disorders (TMD) before and after speech therapy intervention with and without the use of therapeutic elastic bandage. Methods: The collection included 14 female participants, aged between 18 and 40 years, who had a diagnosis of muscular or mixed TMD. The patients were divided into two groups: with traditional therapy (CB) bandage and traditional therapy (SB) only group. The patients underwent initial evaluation, as well as surface electromyography in situations of maximum voluntary contraction and rest and at the end of the four weeks of intervention, a new evaluation was performed with the same instruments. Data analysis occurred quantitatively and qualitatively. Results: In the SB group, the right masseter muscle showed a significant increase in resting values. It was observed that the same occurred for all muscles in this group, influencing the balance of the ipsilateral and contralateral muscles, although without statistical evidence. The CB group did not show statistically significant values, but qualitatively the muscle rest values decreased and balanced in a contralateral way. Conclusion: No statistically significant changes were observed in the resting electromyographic thresholds of the masseter and temporalis muscles in both groups. Qualitatively, there was an increase in electromyographic values after traditional manual therapy in all muscles in the SB group. Regarding the CB group, there was a decrease in electromyographic resting values after therapy, although without statistical evidence. (AU)


Objetivo: La investigación tiene como objetivo verificar los umbrales electromiográficos de reposo de los músculos masetero y temporal en pacientes con trastornos temporomandibulares (TMD) antes y después de la terapia del habla con y sin el uso de venda elástica terapéutica. Métodos: La colección incluyó a 14 participantes mujeres, con edades entre 18 y 40 años, diagnosticadas con TTM muscular o mixta. Los pacientes fueron divididos en dos grupos clasificados en: pacientes con vendaje asociado a terapia tradicional (CB) y grupo de terapia tradicional (SB). Los pacientes fueron inicialmente evaluados mediante electromiografía de superficie en situaciones de máxima contracción voluntaria y reposo, luego de cuatro semanas de intervención se realizó una nueva evaluación con los mismos instrumentos. El análisis de datos se llevó a cabo cuantitativa y cualitativamente. Resultados: En el grupo SB, el músculo masetero derecho presentó un aumento significativo en los valores de reposo, se observó que lo mismo ocurrió para todos los músculos de este grupo, influyendo en el equilibrio de los músculos ipsilaterales y contralaterales, sin embargo, sin evidencia estadística. El grupo CB no mostró valores estadísticamente significativos, pero cualitativamente los valores de descanso muscular disminuyeron y se equilibraron contralateralmente. Conclusión: No se observaron cambios estadísticamente significativos en los umbrales electromiográficos en reposo de los músculos masetero y temporal en ambos grupos. Cualitativamente, hubo un aumento de los valores electromiográficos después de la terapia manual tradicional en todos los músculos del grupo SB. En cuanto al grupo CB, hubo una disminución de los valores electromiográficos de reposo después de la terapia, aunque sin evidencia estadística. (AU)


Subject(s)
Humans , Female , Adolescent , Adult , Electromyography , Masticatory Muscles , Muscle Relaxation/physiology , Temporomandibular Joint Dysfunction Syndrome/therapy , Musculoskeletal Manipulations , Athletic Tape , Controlled Before-After Studies
6.
Conscientiae Saúde (Online) ; 22: e23446, 01 jun. 2023.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1552280

ABSTRACT

Introdução: A eletromiografia (EMG) tem sido utilizada para avaliar alterações no sistema mastigatório proporcionada pela disfunção temporomandibular (DTM). Objetivos: Verificar a confiabilidade teste-reteste de um protocolo de coleta do sinal EMG do músculo masseter em indivíduos com DTM. Métodos: Estudo transversal composto por 20 indivíduos com DTM. Os testes foram realizados em duas sessões com 7 dias de intervalo. O sinal EMG foi avaliado pelas variáveis integral (iEMG) e a raiz quadrada da média do sinal (RMS). Resultados: Na análise intradia a confiabilidade para o RMS (ICC2,k: 0.85 a 0.96 ) e iEMG ICC2,k: 0.85 a 0.95) foi excelente, enquanto que a confiabilidade teste/reteste foi pobre para ambas as variáveis RMS (ICC2,1: 0.03 a 0.29) e iEMG (ICC2,1: 0.08 a 0.39). Conclusões: O protocolo de coleta do sinal EMG do músculo masseter em indivíduos com DTM demonstrou que os dados são reprodutíveis somente na mesma sessão de coletas enquanto que, para coletas em dias alternados a confiabilidade foi pobre.


Introduction: Electromyography (EMG) has been used to assess alterations in the masticatory system caused by temporomandybular disorders (TMD). Objectives: The aim of this study was to verify the test-retest reliability of a protocol for recording the EMG signal from masseter muscle in TMD patients. Methods: This is a cross-sectional study comprising 20 individuals with TMD. Tests were performed in two sessions 7 days apart. The EMG signal was evaluated by the variables integral (iEMG) and the root mean square of the signal (RMS). Results: In the intraday analysis the reliability for the RMS (ICC2,k: 0.85 to 0.96) and iEMG (ICC2,k: 0.85 to 0.95) was excellent, while the test/retest reliability was poor for both RMS (ICC2,1: 0.03 to 0.29) and iEMG (ICC2,1: 0.08 to 0.39) variables. Conclusions: The protocol for collecting the EMG signal from the masseter muscle in an individual with TMD demonstrated that the data are reproducible only in the same recording session, whereas for c recording on alternate days, the reliability was poor.

7.
Rev. bras. ortop ; 58(2): 290-294, Mar.-Apr. 2023. tab
Article in English | LILACS | ID: biblio-1449802

ABSTRACT

Abstract Objective Given the divergence of opinions on the need for complementary tests such as ultrasonography (US) and electroneuromyography (ENMG) for the diagnosis of carpal tunnel syndrome (CTS), we aimed to elucidate which of them presents greater accuracy for the confirmation of the presence or not of this condition. Methods A total of 175 patients from a hand surgery outpatient clinic were clinically evaluated, and the results of clinical trials (Tinel, Phalen and Durkan), US (normal or altered), and ENMG (normal, mild, moderate and severe) were noted, crossed, and submitted to a statistical analysis to verify the agreement between them. Results with the sample had a mean age of 53 years, with a prevalence of female patients (159 cases). Of the patients with positive clinical test, 43.7% had normal US and 41.7% had no alterations on the ENMG. Negative results were found on the Tinel in 46.9%, on the Phalen in 47.4%, and on the Durkan in 39.7%. In the crossing between the results of the ENMG and those of the other diagnostic methods, there was little statistical agreement between them. Conclusion There was no agreement between the results of the clinical examinations, the US and the ENMG in the diagnosis of CTS, and there is no clinical or complementary examination for CTS that accurately determines the therapeutic approach. Level of Evidence IV, Case Series.


Resumo Objetivo Diante da divergência sobre a necessidade de exames complementares, como ultrassonografia (US) e eletroneuromiografia (ENMG) para o diagnóstico da síndrome do túnel do carpo (STC), objetivamos elucidar qual deles apresenta maior precisão na confirmação da presença ou não desta afecção. Métodos Um total de 175 pacientes de um ambulatório de cirurgia da mão foram avaliados clinicamente, e os resultados dos testes clínicos (Tinel, Phalen e Durkan), da US (normal ou alterada) e da ENMG (normal, leve, moderada e grave) foram anotados, cruzados, e submetidos a análise estatística para verificar a concordância entre eles. Resultados A idade média da amostra era de 53 anos, sendo prevalente o sexo feminino (159 casos). Dos pacientes com teste clínico positivo, 43,7% apresentavam US normal, e 41,7%, ENMG sem alterações. Foram encontrados resultados negativos no Tinel em 46,9% no Phalen em 47,4%, e no Durkan em 39,7%. No cruzamento entre a ENMG e os demais métodos diagnósticos, houve pouca concordância estatística. Conclusão Não houve concordância entre os resultados dos exames clínicos, da US e da ENMG no diagnóstico da STC, e não há exame clínico ou complementar para STC que determine a conduta terapêutica com precisão. Nível de Evidência IV, Série de Casos.


Subject(s)
Humans , Paresthesia , Carpal Tunnel Syndrome/diagnosis , Median Neuropathy/diagnosis , Electromyography
8.
CoDAS ; 35(3): e20210161, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1439942

ABSTRACT

RESUMO A intervenção mioterápica em estética facial tem como meta atenuar rugas e sinais de envelhecimento facial. A relação entre contração exagerada dos músculos durante a mastigação, deglutição e comunicação oral e aparecimento de rugas faciais é preconizada na literatura fonoaudiológica neste campo de atuação. Este estudo teve por objetivo relatar o efeito da utilização do biofeedback eletromiográfico associado ao treinamento dos padrões de mastigação, deglutição e sorriso, durante intervenção fonoaudiológica direcionada à atenuação de rugas e sulcos faciais, em mulher de 55 anos de idade. O programa terapêutico incluiu exercícios isotônicos, isométricos e procedimentos clínicos para diminuir a contração dos músculos mímicos faciais, que não foram associados ao treinamento com biofeedback eletromiográfico. A coleta de sinais e o treinamento com o software Biotrainer foram realizados com o aparelho New Miotool Face (Miotec) em nove sessões realizadas semanalmente. Foram realizadas duas avaliações (antes e após as nove sessões), por meio do Protocolo MBGR (avaliação da mastigação, deglutição e sorriso) e de escalas validadas descritas na literatura (avaliação dos sinais de envelhecimento facial). No caso descrito, constatou-se o efeito adjuvante do biofeedback eletromiográfico no aprendizado dos padrões miofuncionais orofaciais treinados, como também, a melhoria das funções mastigação e deglutição e a diminuição dos sinais de envelhecimento facial. Porém, são necessárias pesquisas mais robustas que comprovem efeitos positivos do biofeedback eletromiográfico associado à terapia miofuncional direcionada a atenuar os sinais de envelhecimento facial.


ABSTRACT Myotherapy intervention in facial aesthetics aims to attenuate wrinkles and signs of facial aging. The relationship between accentuated muscle contraction during chewing, swallowing and speaking and the appearance of facial wrinkles has been suggested by speech-language pathology literature. This study aimed to report the effect of electromyographic biofeedback associated with training of chewing, swallowing, and smiling patterns, during speech therapy intervention aimed at reducing the signs of facial wrinkles and furrows, in a 55-year-old woman. The therapy also included isotonic and isometric exercises and clinical procedures to decrease the contraction of facial mimicry muscles, which were not associated with training using electromyographic biofeedback. Signal collection and training were performed using the Biotrainer software on the New Miotool Face by Miotec, over nine weekly sessions. Two assessments were performed (before and after the nine sessions), using the MBGR Protocol (assessment of chewing, swallowing, and smiling) and validated scales described in the literature (assessment of signs of facial aging). In the reported case, the usefulness of electromyographic biofeedback was verified for learning trained orofacial myofunctional patterns, as well as to improve chewing and swallowing functions and decrease signs of facial aging. However, further research is needed to demonstrate the positive effects of electromyographic biofeedback associated with myofunctional therapy aimed at attenuating the signs of facial aging.

9.
Fisioter. Mov. (Online) ; 36: e36115, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1440126

ABSTRACT

Abstract Introduction Urinary incontinence is defined as any involuntary loss of urine. An imbalance in the transmission of forces between the bladder and urethra, associated with deficient support of the pelvic floor muscles, contributes to an alteration in balance in women. Objective To compare balance between continent and incontinent women. Methods This was a cross-sectional study with 13 women divided into incontinent (age: 41.50 ± 9.13 years) and continent (age: 35.29 ± 4.99 years) groups. Balance assessments were performed using a force platform and electromyography: standing, with eyes open (BI_OA); standing, with eyes closed (BI_OF); standing on foam, with eyes open (ESP_OA) and closed (ESP_OF); and standing with unipedal support, with eyes open (UNI_OA). Statistical analysis was initiated after resampling of the original data using the bootstrap technique, with the α value set at 5% (p < 0.05). Results In the BI_OA task, no significant differences were found between the groups. In the BI_OF task, incontinent women showed greater displacement in the anteroposterior axis (p < 0.001), and continent women showed greater displacement in the mediolateral axis (p = 0.008). In the ESP_OA task, incontinent women showed greater displacement in both the COP_X (p = 0.003) and COP_Y (p = 0.001) axes; in the ESP_OF task, continent women showed greater displacement in the COP_X (p < 0.001) axis. In the UNI_OA task, greater anteroposterior displacement was observed among incontinent women (p = 0.008). Conclusion Continent women showed greater displacement in the mediolateral axis in the tasks with eyes closed, and incontinent women showed greater displacement in the anteroposterior axis in the BI_OF, ESP_OA, and UNI_OA tasks.


Resumo Introdução A incontinência urinária é definida como qualquer perda involuntária de urina. Um desequilíbrio na transmissão de forças entre bexiga e uretra, associado a um suporte deficitário dos músculos do assoalho pélvico, contribui para uma alteração no equilíbrio de mulheres. Objetivo Comparar o equilíbrio entre mu-lheres continentes e incontinentes. Métodos Trata-se de um estudo transversal, com 13 mulheres divididas em incontinentes (idade: 41,50 ± 9,13 anos) e continentes (idade: 35,29 ± 4,99 anos). A avaliação do equilíbrio foi realizada na plataforma de força associada à eletromi-ografia: em pé, com olhos abertos (BI_OA); em pé, com olhos fechados (BI_OF); em pé sobre uma espuma, com olhos abertos (ESP_OA) e fechados (ESP_OF); e em pé com apoio unipodal, com olhos abertos (UNI_OA). A análise estatística foi iniciada após a reamostragem dos dados originais pela técnica Bootstrap, com valor de α fixado em 5% (p < 0,05). Resultados Na avaliação do equilíbrio BI_OA, não foram encontradas diferenças significativas entre os grupos. No BI_OF, as mulheres incontinentes apresentaram maior deslocamento no eixo anteroposterior (p < 0,001), enquanto as continen-tes, no médio-lateral (p = 0,008). Na tarefa ESP_OA, as incontinentes apresentaram maior deslocamento em ambos os eixos COP_X (p = 0,003) e COP_Y (p = 0,001); já na ESP_OF, as continentes apresentaram maior deslocamento no COP_X (p < 0,001). Na tarefa UNI_OA, observou-se maior deslocamento anteroposterior entre as incontinentes (p = 0,008). Conclusão Mulheres continentes apresentaram maiores deslocamentos no eixo médio-lateral nas tarefas de olhos fechados, enquanto as incontinentes, no eixo anteroposterior nas tarefas BI_OF, ESP_OA, UNI_OA.

10.
CoDAS ; 35(2): e20210262, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1430235

ABSTRACT

ABSTRACT Purpose To analyze the effects of lingual frenotomy on the breastfeeding of infants, based on the electrical activity of the masseter and suprahyoid muscles and assessment of the breastfeeding. Methods Observational study developed between October 2017 and June 2018 with a sample of 20 newborns and infants who attended a dental clinic and were diagnosed with ankyloglossia. Another 20 were excluded for meeting some of the following exclusion criteria: babies more than 6 months old, who were not on exclusive or mixed breastfeeding, who had other clinical impairments that interfered with breastfeeding, who had other foods introduced into their diet, who had neurological changes and/or craniofacial deformities, and/or who did not finish all the stages of the study. Breastfeeding was assessed with the UNICEF Breastfeeding Assessment and Observation Protocol, while the muscle electrical activity was assessed with the Electrical Activity Assessment Protocol for the Masseter and Suprahyoid Muscles in Newborns During Breastfeeding. The same speech-language-hearing therapist conducted the two assessments both before the conventional frenotomy and 7 days after it. Results The signs suggestive of breastfeeding difficulties changed 7 days after the surgery, with a p-value ≤ 0.002 for general observation of the mother, position of the infant, latch, and sucking. The maximum voluntary contraction of the masseter was the only integral parameter with a difference, as the electrical activity had decreased. Conclusion Behaviors favorable to breastfeeding increased 7 days after the frenotomy in all the breastfeeding assessment categories, whereas the electrical activity of the masseter decreased.


RESUMO Objetivo Analisar os efeitos da frenotomia lingual na amamentação de recém-nascidos, com base na atividade elétrica dos músculos masseter e supra-hióideos e avaliação da mamada. Método Estudo observacional, desenvolvido entre outubro de 2017 e junho de 2018. Amostra de 20 recém-nascidos e lactentes de uma clínica odontológica, diagnosticados com anquiloglossia; 20 foram excluídos por se encaixarem em algum dos critérios de exclusão: ter mais de seis meses de vida, não fazer aleitamento materno exclusivo ou misto, apresentar outro comprometimento clínico que interfira na amamentação, ter iniciado a ingestão de outros alimentos, alterações neurológicas e/ou deformidades craniofaciais e não ter finalizado todas as etapas do estudo. A avaliação da amamentação seguiu o Protocolo de Observação e Avaliação da Mamada da UNICEF, e a avaliação da atividade elétrica muscular o Protocolo de Avaliação da Atividade Elétrica dos Músculos Masseter e Supra-hióideos em Recém-Nascidos Durante a Alimentação, ambas realizadas pela mesma fonoaudióloga antes da frenotomia convencional e sete dias após. Resultados Os sinais sugestivos de dificuldade na amamentação mudaram sete dias após a cirurgia, com valor de p≤0,002 para a observação geral da mãe, posição do bebê, pega e sucção. Houve diferença apenas no parâmetro integral da Contração Voluntária Máxima do masseter, com diminuição da atividade elétrica. Conclusão Sete dias após a frenotomia observou-se aumento de comportamentos favoráveis ​​à amamentação em todas as categorias de avaliação da mamada e diminuição da atividade elétrica do masseter.

11.
Dental press j. orthod. (Impr.) ; 28(1): e232198, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1430271

ABSTRACT

ABSTRACT Introduction: The emergence of orthodontic aligners has provided an aesthetic and comfortable option for orthodontic treatment. However, the encapsulated design of the aligners can influence the masticatory muscles, and might compromise safe treatment. Objective: This preliminary longitudinal study aimed to investigate whether the use of orthodontic aligners affects the biting force and myoelectric activity of the superficial masseter and anterior temporal muscles. Methods: Ten subjects participated in the study and underwent treatment during an 8-month follow-up period. The root mean square (RMS), the median power frequency (MPF) of the surface electromyography (sEMG) signals, and the biting force (kgf) were recorded and normalized relative to the pretreatment condition. The data were analyzed by repeated-measure analysis of variance (ANOVA), with the significance level set at 5%. Results: Both the superficial masseter and the anterior temporal muscles presented an increase in sEMG signal activity during the treatment, with a marked increase in the latter compared to the former (p<0.05). Moreover, a significant decrease in bite force was evidenced (p<0.05). Conclusions: This preliminary study observed that the orthodontic aligners affected the muscle recruitment pattern of masticatory muscles, and reduced biting performance during the 8-month follow-up period.


RESUMO Introdução: O surgimento dos alinhadores ortodônticos tem proporcionado uma opção estética e confortável para o tratamento ortodôntico. No entanto, o design encapsulado dos alinhadores pode influenciar os músculos mastigatórios e comprometer a segurança do tratamento. Objetivo: Este estudo longitudinal preliminar teve como objetivo investigar se o uso de alinhadores ortodônticos afeta a força de mordida e a atividade mioelétrica dos músculos masseter superficial e temporal anterior. Métodos: Dez indivíduos participaram do estudo e foram submetidos a tratamento durante um período de acompanhamento de 8 meses. A raiz quadrada média (RMS), a frequência mediana de potência (FMP) dos sinais de superfície da eletromiografia (sEMG) e a força de mordida (kgf) foram registradas e normalizadas em relação à condição de pré-tratamento. Os dados foram analisados por análise de variância para medidas repetidas (ANOVA), com nível de significância estabelecido em 5%. Resultados: Tanto o masseter superficial quanto o temporal anterior apresentaram aumento da atividade do sinal sEMG durante o tratamento, com aumento acentuado desse último em comparação ao primeiro (p<0,05). Além disso, foi evidenciada uma diminuição significativa da força de mordida (p<0,05). Conclusões: Esse estudo preliminar observou que os alinhadores ortodônticos afetaram o padrão de recrutamento muscular dos músculos mastigatórios e reduziram o desempenho da mordida durante o período de acompanhamento de oito meses.

12.
Fisioter. Pesqui. (Online) ; 30: e21002523en, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1430332

ABSTRACT

ABSTRACT Patellofemoral pain (PFP) may contribute to less activation of the quadriceps muscle, favoring joint overload and pain. Neuromuscular efficiency (NME) is a variable that evaluates the relationship between the amount of neural stimuli and the ability to generate force of in a given muscle, with the most efficient being the one that produces greater muscle force, with less activation of muscle fibers. In this sense, this study aimed to evaluate the strength and NME of knee extensors in women with and without patellofemoral pain. A total of 24 adult women, recruited via a questionnaire, aged from 18 to 30 years, with and without patellofemoral pain, participated in this study. Anamnesis, anterior knee pain scale, and numerical visual scale were applied. Subsequently, the knee extensor strength, with a hand-held dynamometer, and the NME of vastus medialis (VM), vastus lateralis (VL), and rectus femoris (RF) were assessed. For statistical analysis, appropriate tests were adopted to compare variables between groups and correlate them. In all statistical tests, a α<0.05 was adopted. Results showed that women with PFP had 61% lower NME in the VM and 52% in the VL, compared to the group without pain. No significant difference was found for knee extensor strength between groups. We conclude that pain negatively influences VM and VL recruitment but does not change quadriceps ability to generate strength.


RESUMEN El dolor patelofemoral (DPF) puede producir una menor activación del músculo cuádriceps, lo que lleva a una mayor sobrecarga y dolor en esta articulación. La eficiencia neuromuscular (ENM) es una variable que evalúa la relación entre la cantidad de estímulos neurales y la capacidad de determinado músculo de generar fuerza, con más eficiencia para el que produce mayor fuerza muscular, con menor activación de las fibras musculares. Así el objetivo del estudio fue evaluar la fuerza y la ENM de los extensores de rodilla en mujeres con y sin dolor patelofemoral. En este estudio participaron 24 mujeres, con edades entre 18 y 30 años, con y sin dolor patelofemoral, que han sido reclutadas por medio de un cuestionario. Se aplicaron la anamnesis, la escala de dolor anterior de rodilla y la escala visual numérica. Posteriormente, se realizaron evaluaciones de la fuerza extensora de la rodilla con dinamómetro manual y de la ENM del vasto medial (VM), vasto lateral (VL) y recto femoral (RF). Para el análisis estadístico, se adoptaron pruebas apropiadas para comparar variables entre grupos y correlacionarlas. En todas las pruebas estadísticas, el nivel de significación fue de α<0,05. Los resultados mostraron que las mujeres con DPF tenían el 61% menor ENM en el VM y el 52% en el VL en comparación con el grupo sin dolor. No hubo diferencias significativas para la fuerza extensora de la rodilla entre los grupos. Se concluye que el dolor influye negativamente en el reclutamiento de VM y VL, pero no cambia la capacidad de generar fuerza del cuádriceps.


RESUMO A dor patelofemoral (DPF) pode contribuir para menor ativação do músculo quadríceps, favorecendo maior sobrecarga e dor nesta articulação. A eficiência neuromuscular (ENM) é uma variável que avalia a relação entre a quantidade de estímulos neurais e a capacidade de geração de força de um determinado músculo, sendo mais eficiente aquele que produz maior força muscular, com menor ativação das fibras musculares. Nesse sentido, o objetivo do estudo foi avaliar a força e a ENM dos extensores de joelho em mulheres com e sem dor patelofemoral. Participaram deste estudo 24 mulheres, recrutadas por meio de um questionário, com idades entre 18 e 30 anos, com e sem dor patelofemoral. Foram realizadas a anamnese, a escala de dor anterior no joelho e a escala visual numérica e, posteriormente, a avaliação da força extensora de joelho, com dinamômetro manual, e a avaliação da ENM de vasto medial (VM), vasto lateral (VL) e reto femoral (RF). Para análise estatística, foram adotados os testes apropriados para comparação das variáveis entre os grupos e para correlação entre elas. Em todos os testes estatísticos foi adotado o nível de significância de α<0,05. Os resultados mostraram que mulheres com DPF apresentaram 61% menor ENM do VM e 52% do VL, em comparação ao grupo sem dor. Não se encontrou diferença significativa para força extensora de joelho entre os grupos. Concluímos que a dor influencia negativamente o recrutamento de VM e VL, mas não altera a capacidade do quadríceps de gerar força.

13.
Fisioter. Mov. (Online) ; 36: e36131, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520910

ABSTRACT

Abstract Introduction Spinal cord injury generates muscle weakness, impairing orthostatism and gait. The elliptical trainer (ET) and the ergometric bicycle (EB) are rehabilitation options for this subject. Understanding the pattern of muscle activation generated by these methods is important to answer questions arising from clinical practice. Objective To verify muscle activation with ET and EB with and without electromyographic biofeedback in subjects with incomplete spinal cord injury (ISCI). Methods Cross-sectional crossover study, enrolled in Clinical Trials (NCT05118971). Subjects with spinal cord injury (incomplete spinal cord injury group - ISCIG) and without spinal cord injury (reference group - RG) were randomized into four groups: elliptical group (EG), elliptical + biofeedback group (EBG), bicycle group (BG) and bicycle + biofeedback group (BBG). Subjects were assessed for functionality by the Functional Independence Measure, injury classification by the ASIA Scale, muscle tone by the modified Ashworth scale, and muscle activity by electromyography. Results There was greater activation of the tibialis anterior on cycling compared to other modalities in ISCIG. Biofeedback offered no difference in any of the groups. In RG the vastus medialis was the most activated muscle in all modalities, with more expressive activation in the ET. In this same group, the tibialis anterior was more activated on the EB. Conclusion This study showed that both ET and EB are safe and effective in recruiting the muscles investigated, encouraging its use by rehabilitation professionals when the objective is to strength muscles involved in gait.


Resumo Introducão A lesão medular gera fraqueza muscular, preju-dicando o ortostatismo e a marcha. O aparelho elíptico (EL) e a bicicleta ergométrica (BE) são opções de reabilitação para estes sujeitos. Compreender o padrão de ativação muscular gerado por esses métodos é importante para esclarecer dúvi-das advindas da prática clínica. Objetivo Verificar a ativação muscular com EL e BE com e sem biofeedback eletromiográfico em indivíduos com lesão medular incompleta (LMI). Métodos Estudo transversal do tipo crossover, inscrito no Clinical Trials (NCT05118971). Sujeitos com lesão medular (grupo lesão medular incompleta - GLMI) e sem lesão medular (grupo refe-rência - GR) foram randomizados em quatro grupos: elíptico (GE), elíptico + biofeedback (GEB), bicicleta (GB) e bicicleta + biofeedback (GBB). Os indivíduos foram avaliados quanto à funcionalidade pela Medida de Independência Funcional, classificação da lesão pela Escala ASIA, tônus muscular pela escala modificada de Ashworth e atividade muscular por eletromiografia. Resultados Houve maior ativação do tibial anterior no ciclismo em comparação com outras modalidades no GLMI. O biofeedback não ofereceu nenhuma diferença em nenhum dos grupos. No GR, o vasto medial foi o músculo mais ativado em todas as modalidades, com ativação mais expressiva no EL. Neste mesmo grupo, o tibial anterior foi mais ativado na BE. Conclusão Este estudo mostrou que tanto o EL quanto a BE são seguros e eficazes no recrutamento dos músculos investigados, incentivando seu uso por profissionais da reabilitação quando o objetivo é fortalecer os músculos envolvidos na marcha.

14.
Fisioter. Pesqui. (Online) ; 30: e22015123en, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520922

ABSTRACT

ABSTRACT This study aimed to verify the effect of the spring constant change on the electromyographic activity of the powerhouse and shoulder muscles during the long stretch exercise. In total, 15 Pilates practitioners performed the Long Stretch exercise on the reformer with three different spring constants: (1) k=0.19kg/cm with 1 red spring; (2) k=0.27kg/cm with 1 red spring and 1 yellow; and (3) k=0.38kg/cm with 2 red springs. The Electromyographic activity of Rectus Abdominis (RA), External Oblique (EO), Internal Oblique/Transversus abdominis (OI/TS), Multifidus (MU), Iliocostalis (IC), Longissimus (LG), Lower Trapezius (LT), and Anterior Deltoid (AD) were evaluated. We observed that as the spring constant increases, the RA, OE, OI/TS muscles decrease their EMG activity, while the AD, LT, and LG increase their EMG activity. The MU and IC muscles were not influenced in their EMG activities. Therefore, we observed an influence of the change of the spring constant on the electromyographic activity of the RA, OE, OI/LG, AD, and LT muscles. However, we found no influence of the spring constant on the EMG activities of the MU and IC muscles during the long stretch.


RESUMEN El objetivo de este estudio fue evaluar el efecto del cambio de la constante de la muelle en la actividad electromiográfica (EMG) de los músculos del powerhouse y del hombro durante el ejercicio de long stretch. En el estudio participaron quince practicantes de pilates que realizaron el ejercicio long stretch en el reformer con tres constantes elásticas: (1) k=0,19kg/cm, representado por 1 muelle roja; (2) k=0,27kg/cm, representado por 1 muelle roja y 1 muelle amarilla; y (3) k=0,38kg/cm, representado por 2 muelles rojas. Se evaluaron las actividades EMG de los músculos recto abdominal (RA), oblicuo externo (OE), oblicuo interno/transverso (OI/TS), multífidos (MU), iliocostal (IC), longuissimus (LG), deltoides anterior (DA) y trapecio inferior (TI). Se pudo observar que a medida que aumenta la constante elástica de la muelle, los músculos RA, OE, OI/TS disminuyen su actividad EMG, mientras que los músculos DA, TI y LG aumentan su actividad EMG. Los músculos MU e IC no fueron influenciados en sus actividades EMG. Se puede concluir que hubo influencia del cambio en la constante elástica de la muelle sobre la actividad EMG de los músculos RA, OE, OI/TS, LG, DA y TI durante el long stretch, pero no hubo influencia en las actividades EMG de los músculos MU e IC.


RESUMO O objetivo deste estudo é verificar o efeito da mudança da constante elástica na atividade eletromiográfica (EMG) dos músculos do powerhouse e do ombro durante o exercício de long stretch. Participaram da pesquisa 15 praticantes de Pilates que executaram o exercício de long stretch no reformer com três constantes elásticas: (1) k=0,19kg/cm, representado por uma mola vermelha; (2) k=0,27kg/cm, representado por uma mola vermelha e uma mola amarela; e (3) k=0,38kg/cm, representado por duas molas vermelhas. Foram avaliadas as atividades EMGs dos músculos reto abdominal (RA), oblíquo externo (OE), oblíquo interno/transverso (OI/TS), multífidos (MU), iliocostal (IC), longuíssimo (LG), deltoide anterior (DA) e trapézio inferior (TI). Pode-se observar que, conforme a constante elástica aumenta, os músculos RA, OE, OI/TS diminuem suas atividades EMG, enquanto os músculos DA, TI e LG as aumentam. Os músculos MU e IC não foram tiveram suas atividades EMG influenciadas. Portanto, conclui-se que houve influência da mudança da constante elástica sobre as atividades EMG dos músculos RA, OE, OI/TS, LG, DA e TI durante o long stretch, mas não nas atividades EMG dos músculos MU e IC.

15.
CoDAS ; 35(6): e20220053, 2023. tab
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1514015

ABSTRACT

RESUMO Objetivo correlacionar os achados da avaliação clínica miofuncional orofacial, pressão de língua e da eletromiografia de superfície (EMGs) da deglutição de grupos de pacientes com diferentes alterações da motricidade orofacial. Método 44 pacientes (20 homens e 24 mulheres com idades entre 17 e 63 anos), com diferentes alterações miofuncionais orofaciais foram avaliados por meio da Avaliação Miofuncional Orofacial com Escores Expandido (AMIOFE-E), avaliação da amplitude mandibular e antropometria facial, mensuração da pressão de língua (ponta e dorso) e exame de Eletromiografia de Superfície (EMGs) em região supra hioidea na tarefa de deglutição de saliva e diferentes volumes de água. Resultados a análise estatística encontrou algumas correlações fracas que envolvem a pressão do dorso de língua e sugerem que quanto maior for a medida do terço inferior, menor será a pressão do dorso da língua; quanto maior for a medida dos trespasses (vertical e horizontal) maior será a pressão do dorso da língua; quanto maior for a pontuação da avaliação de postura e funções orofaciais, maior será a pressão do dorso de língua e quanto maior for a pressão do dorso de língua, maior será a pressão da ponta da língua. Conclusão os resultados sugerem que as alterações miofuncionais orofaciais encontradas nos diferentes grupos de pacientes estão mais relacionadas às discrepâncias maxilomandibulares do que às patologias pesquisadas no presente estudo.


ABSTRACT Purpose To correlate the findings regarding the myofunctional orofacial examination, tongue pressure and surface electromyography (sEMG) of deglutition in individuals with different orofacial myofunctional disorders. Methods 44 patients (20 males and 24 females, aged between 17 and 63 years old) with different orofacial myofunctional changes were clinically assessed using the Expanded Protocol of Orofacial Myofunctional Evaluation with Scores (OMES-E). In addition, the range of mandibular movements and facial anthropometry were measured, along with the assessment of the tongue pressure (tip and dorsum) and of the electrical activity of the suprahyoid muscles during deglutition, using surface electromyography (sEMG). Results The statistical analysis found weak correlations between tongue dorsum pressure values, suggesting that the greater the measurement of the lower third of the face, the lower the pressure of the tongue dorsum; the greater the measurement of the overlaps (vertical and horizontal), the higher the pressure of the tongue dorsum; the higher the score from the orofacial evaluation and orofacial functions assessment, the higher the pressure of the tongue dorsum; and the higher the pressure of the tongue dorsum, the higher the pressure of the tongue tip. Conclusion The present study results indicate that the orofacial myofunctional changes found in different groups of patients are more related to the maxillomandibular discrepancies than to the pathologies investigated herein.

16.
Acta fisiátrica ; 29(4): 295-301, dez. 2022.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1416510

ABSTRACT

Objetivo: Verificar se existe correlação entre excitabilidade central e periférica após o treino com a terapia de restrição induzida do movimento (TRIM) modificada associada a contensão de tronco para o membro superior parético após Acidente Vascular Encefálico (AVE). Métodos: Ensaio clínico controlado onde vinte e dois voluntários foram selecionados e randomizado em dois grupos: Grupo Controle (GC) e Grupo Experimental (GE). Eles foram avaliados por meio do eletroencefalograma (EEG) e da eletromiografia (EMG) de superfície. Os canais EEG analisados foram: Canal Ântero Frontal (AF3/AF4); Canal Frontal região medial (F7/F8); Canal Frontal região lateral (F3/F4); Canal Fronto Central (FC5/FC6); Região temporal (T7/T8); Região occipital (O1/O2). Os músculos analisados com EMG foram bíceps braquial, flexores e extensores de punho. As avaliações foram realizada durante a atividade, por dez minutos. O GE recebeu o treinamento com TRIM modificada uma hora por dia, duas semanas consecutivas. Resultados: O GC (pós-intervenção) apresentou correlação moderada negativa (r= -0,69; p= 0,02) do canal Fa com extensor de punho. O GE apresentou (pré-intervenção) correlação moderada negativa do canal AF (r= -0,68; p= 0,02) e FC (r= -0,71; p= 0,01) com flexor de punho. Na pós intervenção apresentou correlação positiva do canal Fa (r= 0,61; p= 0,04) com o extensor de punho. Conclusão: A TRIM modificada associada à contensão de tronco para o membro superior parético apresentou correlação positiva do canal Fa com o músculo extensor de punho e o grupo não treinado apresentou correlação negativa do canal Fa com extensor de punho.


Objective: Establish the correlation between central and peripheral excitability after training with the modified upper limb constraint-induced movement therapy (CIMT) associated with trunk constraint for patients with stroke. Methods: This study is a randomized clinical trial. Twenty-two volunteers were included and randomized into the Control (CG) and Experimental Groups (EG). They were assessed with electroencephalography (EEG) and surface electromyography (EMG). The EEG channels analyzed were antero-frontal (AF3/AF4), frontal-medial (F7/F8), frontal-lateral (F3/F4), frontal-central (FC5/FC6), temporal (T7/T8), and occipital (O1/O2). The muscles evaluated with EMG were biceps brachii, wrist flexors, and wrist extensors. The evaluations were performed simultaneously with a functional assessment for ten minutes. The EG received the modified CIMT training one hour per day for two consecutive weeks. Results: After the intervention, the CG showed a moderate negative correlation of the Fa channel with the wrist extensor (r= -0.69; p= 0.02), whereas the EG had a moderate negative correlation of the FA channel (r= -0.68; p= 0.02) and FC (r= - 0.71; p= 0.01) with wrist flexor. In the post-intervention, a positive correlation of the FA channel was found with the wrist extensor (r= 0.61; p= 0.04). Conclusion: The modified CIMT associated with the trunk constraint for the paretic upper limb showed a positive correlation between the Fa channel and the wrist extensor muscle, and the control group showed a negative correlation between the Fa channel and the wrist extensor.

17.
Arq. neuropsiquiatr ; 80(8): 831-836, Aug. 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1403525

ABSTRACT

Abstract Background Cutaneous silent period (CSP) is the interruption in muscle activity after painful stimulation of a sensory nerve. Objective The aim of the present study is to assess CSP changes in patients with polyneuropathy (PNP). Methods The present study was carried out to assess CSP in individuals with diabetes (DM) and Charcot-Marie-Tooth (CMT) disease. The sample comprised 24 individuals with DM, 10 individuals with CMT1 disease, and 10 individuals with CMT2 disease. The control group (CG) consisted of 59 individuals. Results The mean latencies recorded for the upper limbs in the CG were 79.2 milliseconds (onset latency), 69.3 milliseconds (50% reduction latency), 112.2 milliseconds (end latency), and 33.1 milliseconds (CSP duration). On the other hand, the mean latencies recorded for the lower limbs were 99.0 milliseconds (onset latency), 85.0 milliseconds (50% reduction latency), 136.9 milliseconds (end latency), and 38.2 milliseconds (CSP duration). The mean latencies recorded for the CG were significantly lower than the ones recorded for other groups, both in the upper and lower limbs. Conclusions Cutaneous silent period values recorded for the CG in the present study were close to the ones reported in studies available in the literature. Abnormal CSP parameters were observed in the group of individuals with PNP. The end latency in the lower limbs helped differentiating the demyelinating subgroup from the axonal one.


Resumo Antecedentes Período de silêncio cutâneo (PSC) é uma interrupção da atividade muscular após a estimulação dolorosa de um nervo sensitivo. Objetivo O presente estudo tem como objetivo avaliar alterações do PSC em indivíduos com polineuropatia. Métodos O presente estudo avaliou PSC em indivíduos com diabetes mellitus (DM) e com doença de Charcot-Marie-Tooth (CMT). A amostra compreendia 24 indivíduos com DM, 10 indivíduos com CMT tipo 1 e 10 indivíduos com CMT tipo 2. Um grupo controle continha 59 indivíduos. Resultados A média das latências do PSC registradas nos membros superiores no grupo controle foi 79,2 milissegundos (latência de início), 69,3 milissegundos (latência com redução de 50%), 112,2 milissegundos (latência final) e 33,1 milissegundos (duração do PSC). Por outro lado, a média das latências do PSC registradas nos membros inferiores foi 99,0 milissegundos (latência de início), 85,0 milissegundos (latência com redução de 50%), 136,9 milissegundos (latência final) e 38,2 milissegundos (duração do PSC). A média das latências registradas no grupo controle foi significativamente menor do que as registradas nos outros grupos (DM e CMT), tanto nos membros inferiores quanto nos superiores. Conclusões Os valores do PSC registrados no grupo controle no presente estudo estiveram próximos aos reportados na literatura. Parâmetros anormais foram observados no grupo de indivíduos com polineuropatia. A latência final do PSC obtida nos membros inferiores ajudou a diferenciar os subgrupos desmielinizantes e axonais.

18.
Rev. med. (Säo Paulo) ; 101(4): e-173259, jul.-ago. 2022.
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1392116

ABSTRACT

A reabilitação na esteira com suporte parcial de peso (ESPP) nos indivíduos lesados medulares pode reproduzir de modo passivo a marcha, proporcionando-lhes a descarga de peso em membros inferiores (MMII) e a manutenção da postura ortostática. O objetivo do estudo foi analisar se, durante a marcha passiva na ESPP, existe irradiação motora de MMII aos membros superiores. Foram selecionados três indivíduos do gênero masculino, com diagnóstico de Traumatismo Raquimedular baixo (T10 e L1), classificados como ASIA A com preservação parcial de raízes nervosas. Os indivíduos foram submetidos a uma avaliação passiva da marcha na ESSP, utilizando a avaliação eletromiográfica dos músculos: bíceps braquial (BB), reto femoral (RF) e gastrocnêmio lateral (GL) bilateralmente e a uma análise estatística, incluindo testes de Shapiro-Wilk e de Levene, One way ANOVA, post-hoc Tukey HSD. Na condição clínica de repouso, observou-se menor ativação dos músculos BB bilateralmente, quando comparado aos músculos RF e GL, fato justificado pelos comprometimentos secundários advindos da lesão dos indivíduos. As condições clínicas do ciclo da marcha (CM) repetiram-se três vezes; no CM1 observou-se uma maior ativação eletromiográfica do músculo GL direito e uma menor ativação do músculo BB direito, e estatisticamente, GL direito e BB esquerdo demonstraram maior atividade média (resultados estatisticamente significantes). No CM2 o mesmo padrão de ativação do CM1 foi observado, no entanto o músculo RF direito reduziu seu limiar de ativação. No CM3 os níveis de ativação das condições anteriores mantiveram-se, no entanto, o músculo RF esquerdo apresentou aumento nos limiares de ativação eletromiográfica, quando comparado aos demais músculos. Com base nestes resultados, o músculo BB apresentou variações quantitativas na ativação eletromiográfica, determinando a presença de irradiação motora de MMII para superiores durante o CM. Em uma análise qualitativa, foi observado que durante as fases de apoio da marcha houve "picos" de ativação deste músculo. [au]


Rehabilitation on the treadmill with partial body weight support (PBWS) in individuals with spinal cord injuries can passively reproduce gait, helping them with weight bearing on the lower limbs (LL) and orthostatic posture. The objective of the study was to assess motor irradiation from the lower limbs to the upper limbs during gait training with PBWS. The participants were three male individuals diagnosed with low spinal cord injury (T10 and L1), classified as ASIA A, with partial preservation of nerve roots. Subjects were submitted to gait training with PBWS and electromyographic assessment of the muscles Biceps brachii (BB), Rectus femoris (RF) and Lateral Gastrocnemius (LG) on both sides. Statistical analysis included Shapiro-Wilk and de Levene tests, One way ANOVA test and Tukey's HSD post-hoc test. In the resting state, there was less activity of BB muscles on both sides when compared to the RF and LG, which can be explained by the secondary impairments arising from the individuals' injury. The gait cycle (GC) was repeated three times; in GC1 there was greater electromyographic activity in the right LG muscle and lower activity of the right BB muscle and, statistically, right LG and left BB showed higher mean activity (statistically significant results). In GC2, the same pattern of activity of GC1 was observed, but the right RF muscle reduced its activation threshold. In GC3, the activity levels of the previous cycles were maintained, but the left RF muscle showed an increase in the thresholds of electromyographic activation when compared to the other muscles. Based on these results, the BB muscle presented quantitative variations in electromyographic activation, demonstrating the presence of motor irradiation from LL to upper limbs during the GC. The qualitative analysis showed "peaks" of activity in this muscle mainly during the support phases of the gait training. [au]

19.
Rev. MED ; 30(1)jun. 2022.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1535355

ABSTRACT

los músculos masetero y temporal tienen mucha relevancia en el proceso de masticación; además, suelen verse afectados con enfermedades mioarticulares, neurológicas, entre otras. El objetivo de este estudio es presentar los resultados de electromiografía con electrodo de aguja de los músculos masetero y temporal al momento de la masticación, evaluando los parámetros en amplitud y duración de los potenciales obtenidos. Se tomaron veintiséis individuos con previa valoración de odontología que descartaba alteraciones congénitas, defectos de la masticación y con dinamometría normal en momento de mayor oclusión, a los cuales se les realizó electromiografía de aguja en los músculos masetero y temporal en la máxima oclusión; los resultados fueron analizados bajo el estudio de los valores de amplitud máxima y mínima, así como duración ubicando en percentiles y cuadriles, buscando determinar valores que puedan considerarse normales en esta muestra. Al estudiar el músculo temporal se encontró que la duración normal se encuentra entre 4,75 y 6,487 mseg, mientras que la amplitud se encontraría entre 1572,05 uV y 1038,03 uV; en el caso del músculo masetero, se evidenció que la duración normal se encuentra entre 4,03 y 6,767 mseg, mientras que la amplitud se encontraría entre 2838,43 uV y 1864,635 uV. Este estudio da a conocer valores propios para nuestra población en lo que respecta a duración y amplitud de los potenciales de acción de unidad motora de los músculos temporal y masetero, los cuales concuerdan con los establecidos previamente como normales. En estudios previos realizados en otras partes del mundo, se encontró que la duración es menor que en las extremidades, pero la amplitud es similar, aunque con tendencia a valores inferiores al promedio.


The masseter and temporalis muscles are very relevant in the process of mastication. mastication process; they are also often affected by myoarticular and neurological diseases, among others. This study aims to present the results of electromyography with needle electrodes of the masseter and temporalis muscles at the time of mastication, evaluating the parameters in amplitude and duration of the potentials obtained. Twenty-six individuals were taken with a previous dental evaluation that ruled out congenital alterations, masticatory defects, and with normal dynamometry at the moment of maximum occlusion, to whom needle electromyography was performed in the masseter and temporalis muscles at maximum occlusion; the results were analyzed under the study of the maximum and minimum amplitude values, as well as duration located in percentiles and quadrilles, seeking to determine values that could be considered normal in this sample. When studying the temporal muscle, it was found that the normal duration is between 4.75 and 6.487 msec, while the amplitude would be between 1572.05 uV and 1038.03 uV; in the case of the masseter muscle, it was evidenced that the normal duration is between 4.03 and 6.767 msec, while the amplitude would be between 2838.43 uV and 1864.635 uV. This study reveals values specific to our population in terms of duration and amplitude of the motor unit action potentials of the temporalis and masseter muscles, which agree with those previously established as normal. In previous studies performed in other parts of the world, it was found that the duration is shorter than in the extremities. Still, the amplitude is similar, although with a tendency to lower valuesthan the average.


os músculos masseter e temporal são muito importantes no processo de mastigação. Além disso, eles são frequentemente afetados por doenças mioarticulares, neurológicas e outras. O objetivo deste estudo é apresentar os resultados da eletromiografia com eletrodos de agulha dos músculos masseter e temporal no momento da mastigação, avaliando os parâmetros de amplitude e duração dos potenciais obtidos. Foram tomados 26 indivíduos com avaliação odontológica previa que descartou alterações congênitas, defeitos de mastigação e com dinamometria normal quando da oclusão máxima, nos quais foi realizada a eletromiografia de agulha dos músculos masseter e temporal em oclusão máxima; os resultados foram analisados sob o estudo dos valores máximos e mínimos de amplitude, bem como de duração, colocando-os em percentis e quartis, buscando determinar valores que pudessem ser considerados normais nessa amostra. Ao estudar o músculo temporal, verificou-se que a duração normal está entre 4,75 e 6,487 mseg, enquanto a amplitude estaria entre 1572,05 uV e 1038,03 uV; no caso do músculo masseter, verificou-se que a duração normal está entre 4,03 e 6,767 mseg, enquanto a amplitude estaria entre 2838,43 uV e 1864,635 uV. Este estudo revela valores próprios para nossa população em termos de duração e amplitude dos potenciais de ação da unidade motora dos músculos temporal e masseter, que estão de acordo comos valores previamente estabelecidos como normais. Em estudos anteriores realizados em otros lugares, verificou-se que a duração é mais curta do que nas extremidades, mas a amplitude é semelhante, embora com uma tendência a valores mais baixos do que a média.

20.
Distúrb. comun ; 34(2): e52916, jun. 2022. ilus, tab
Article in Portuguese | LILACS | ID: biblio-1396831

ABSTRACT

Objetivo: Correlacionar os dados acústicos da ausculta cervical com a atividade elétrica dos músculos envolvidos na fase faríngea da deglutição. Métodos: Trata-se de um estudo observacional, transversal, de abordagem quantitativa, aprovado em janeiro pelo CEP/UFSCPA (número 1.389.050). Todos os participantes do estudo assinaram o termo de consentimento livre e esclarecido. A fase faríngea da deglutição foi avaliada por meio de ausculta cervical e eletromiografia de superfície. Os indivíduos ingeriram 90 ml de água. Os dados da ausculta foram transferidos para o DeglutiSom® software, a duração e amplitude da atividade eletromiográfica foram mensuradas durante a deglutição com aparelho de eletromiografia de superfície Miotec®. O nível de significância adotado foi de 5%. Resultados:Cinquenta e sete mulheres participaram deste estudo. A média de idade foi de 23,4 anos. Ressalta-se que quanto maior a frequência média do pico da ausculta, menor é a média do pico do músculo supra-hióideo e quanto maior a intensidade, maior é o pico, assim como a média dos picos supra-hióideos. Foi possível demonstrar que o pico de atividade do músculo supra-hióideo foi significativamente maior do que o pico de atividade do músculo infra-hióideo para a deglutição de 90 ml de água. Conclusão:Os parâmetros acústicos da deglutição em indivíduos saudáveis estão correlacionados com a atividade elétrica dos músculos envolvidos na fase faríngea da deglutição.


Objective: Correlate the acoustic data of cervical auscultation to the electrical activity of the muscles involved in the pharyngeal phase of swallowing. Methods: This is an observational, cross-sectional study involving a quantitative approach and was approved on January by CEP/UFSCPA (number 1.389.050). All participants of the study signed an informed consent form. The pharyngeal phase of swallowing was assessed by employing auscultation and surface electromyography. Individuals ingested 90 ml of water. The auscultation data were transferred to DeglutiSom® software, the duration and amplitude of electromyographic activity was measured during swallowing using a Miotec® surface electromyography device. The level of significance adopted was 5%. Results: Fifty-seven women participated in this study. The average age was 23.4 years on average. It must be highlighted that the greater the average peak frequency of auscultation, lower was the average peak of the suprahyoid muscle and the greater the intensity, the greater was the peak, as well as the average of the suprahyoid peaks. It was possible to demonstrate that the peak of suprahyoid muscle activity was significantly higher than the peak of infra hyoid muscle activity for swallowing 90 ml of water. Conclusion: The acoustic swallowing parameters in healthy individuals are correlated with the electrical activity of muscles involved in the pharyngeal phase of swallowing.


Objetivo: Correlacionar los datos acústicos de la auscultación cervical con la actividad eléctrica de los músculos involucrados en la fase faríngea de la deglución. Métodos: Se trata de un estudio observacional, transversal, de abordaje cuantitativo y aprobado en enero por CEP/UFSCPA (número 1.389.050). Todos los participantes del estudio firmaron un formulario de consentimiento informado. La fase faríngea de la deglución se evaluó mediante auscultación y electromiografía de superficie. Los individuos ingirieron 90 ml de agua. Los datos de auscultación fueron cargados em el software DeglutiSom®, la duración y la amplitud de la actividad electromiográfica se midió durante la deglución utilizando un dispositivo de electromiografía de superficie Miotec®. El nivel de significancia adoptado fue del 5%. Resultados: Cincuenta y siete mujeres participaron en este estudio. La edad promedio fue 23,4 años. Cabe destacar que a mayor frecuencia de pico promedio de auscultación, menor fue el pico promedio del músculo suprahioideo y a mayor intensidad, mayor fue el pico, así como el promedio de los picos suprahioideos. Fue posible demostrar que el pico de actividad del músculo suprahioideo era significativamente más alto que el pico de actividad del músculo infrahioideo para tragar 90 ml de agua. Conclusión: Los parámetros de deglución acústica en individuos sanos se correlacionan con la actividad eléctrica de los músculos involucrados en la fase faríngea de la deglución.


Subject(s)
Humans , Female , Adolescent , Adult , Middle Aged , Auscultation , Deglutition/physiology , Electromyography , Correlation of Data , Pharynx , Cross-Sectional Studies , Deglutition
SELECTION OF CITATIONS
SEARCH DETAIL